High temperature chiller/heater heat recovery UCH Climacool

The high temperature heat recovery can be utilized for heating and cooling operations and is compatible with boiler/tower and geothermal systems.

Ask for product

Downloads

Symbol ClimaCool
Profile: Manufacturer
Headquarters: US
Certificates: AHRI
Employees: 50
Assortment: Chillers, Heaters, Heat pumps
UCH 015 Heat recovery
Add to inquiry
UCH 025 Heat recovery
Add to inquiry
UCH 030 Heat recovery
Add to inquiry
UCH 050 Heat recovery
Add to inquiry
UCH 075 Heat recovery
Add to inquiry
UCH 080 Heat recovery
Add to inquiry
Product descritipion

Heat recovery can provide hot water, as high as 135° F, while also producing chilled water. The heat recovery module can reach combined efficiencies of up to 25 EER.

Tonnages: 15, 25, 30, 50, 70, 85
Configurations: 15 - 1,000 tons per bank

A dedication to energy and environmental leadership results in the Ultimate Chiller Solution modular design and fundamental features: compact size, redundant operation, maneuverability, efficiency, reliability and serviceability. Available in 15, 25, 30, 50, 70 and 85 tons which, when combined, tonnages can obtain specific project turndown and capacity requirements from 15 to 1,000 tons per bank while having the ability to accommodate future growth and expansion needs.

Durable

Heavy gauge G90 galvanized steel base and framework with 3 mil powder coat paint finish, baked at 350°F for resilience in transport and installation. Schedule 40 carbon steel pipe water headers are designed to connect to adjacent modules through the use of 300 psi rated grooved couplings.

Energy Efficient

High efficiency design offers up to 16.5 EER at full-load and up to 21.3 EER at part-load (IPLV), exceeding ASHRAE 90.1 minimum efficiency requirements.

Environmentally Friendly

Incremental and minimum overall per ton refrigerant charge. Largest refrigerant circuit contains approximately one pound per ton of charge per module. This typically eliminates the requirement for expensive refrigerant monitoring, ventilation and associated controls. Non-ozone depleting R-410A refrigerant offers better efficiency, higher capacity and utilizes superior synthetic lubricants for longer compressor life.

Integrated CoolLogic Control System

Each module has an independent control panel and simple two-conductor shielded daisy chain connection from the Master Panel to the modules ensuring ultimate performance with minimal field wiring. BAS interface with native BACnet, Modbus, Lonworks and N2 communications.

Maneuverable

All modules fit easily through standard 36” doorways and onto typical freight elevators. Modules are designed with a low center of gravity and base cutouts for forklifts and pallet jacks.

Reliable

Dual scroll compressors with independent refrigerant circuits provide reliable, efficient, quiet and redundant operation. Use of highly efficient, dual circuit brazed plate heat exchangers offer maximum performance at both full-load and part-load conditions.

Service Friendly

Design allows easy access to major components such as compressors, brazed plate heat exchangers, refrigeration components and pete’s ports. Unique design is fully serviceable and maintainable without removal of module from the chiller bank or disassembly of headers.

True Redundancy

Separate module electrical feeds provide true electrical redundancy. Dual independent refrigeration circuits per module provide true mechanical redundancy. Major application flexibility and expandability. Photo shows three 70 ton modules totaling 210 tons capacity. The 15, 25, 30, 50 and 70 ton modules are configurable up to 400 tons per bank. The 85 ton module is configurable up to 1,000 tons per bank.

Options for every application.

Automatic Strainer Package

Field installed high quality stainless steel filtration system with minimum 60 mesh stainless steel screens. Available options include pressure differential alarm and automatic time flush.

Condenser Water Head Pressure Regulating

Control Factory installed motorized condenser water valves provide head pressure regulation for low entering condenser water temperature applications (less than 60°F).

Heat Pump

Factory installed reverse cycle heating and cooling operation compatible with boiler/tower and geothermal systems.

Heat Recovery

Factory installed option that provides hot water, as high as 135°F, while simultaneously producing chilled water for the chiller system.

Hot Gas Bypass

Factory installed on both circuits allowing unit operation below the minimum step of unloading.

Manual Strainers

Field installed to increase efficiency and ensure long life of the equipment with Y-style and basket strainers of cast iron 200 psi or carbon 275 psi with 60 mesh stainless steel screens. All strainers are field installed external to the chiller bank for ease of service.

Pressure Differential Flow Sensor

Field installed to prevent operation of the chiller without sufficient water flow to the evaporator and/or condenser.

Variable Speed Compressor

Factory installed variable frequency drives provide more precise water temperature control and optimum part load energy efficiency.

Water Header Bypass

A field installed water header bypass may be utilized to prevent deadheading the pump.

Water Isolation Valves and Flush Ports

Factory installed to provide isolation to the module for maintenance and cleaning of evaporator and condenser heat exchangers. This is accomplished without increasing unit or bank dimensions while adjacent modules continue normal operation. Optional choice of integral manual or motorized valves includes ¾” fill and flush valves.

LEED categories satisfied by the UCW/H system:

Enhanced Commissioning and Measurement and Verification

CoolLogic Control System provides maximum flexibility with BAS interface.

Enhanced Refrigerant Management

Micro charge of chlorine-free and non-ozone depleting refrigerant.

Optimized Energy Performance

Exceeds ASHRAE 90.1 minimum efficiency.

Sustainable Sites and Building Re-Use

Compact design shrinks mechanical room and building footprint and allows modules to fit through existing doors. This eliminates the need for demolition and reconstruction.

Thermal Comfort

Precise required heating and cooling ensures the highest comfort for building occupants.

Ask for product
What is aeroventic?
  • What is aeroventic?

    Aeroventic is an international solution dedicated to HVACR industry. It has been designed to create an opportunity for both producers and distributors to present their business value and products worldwide. One system allowing for global reach.

  • Company profile

    Build your company value and present your competitive advantage.

    Share your catalogues, software selection programs and all business facts you consider important.

  • Product virtual showroom

    It is a great place to present all your products at once effortlessly.Each product is equipped with an option "Add to inquiry" for customer convenience. A customer sends an inquiry directly to you.

  • News & information channel

    Basically speaking, aeroventic is an equivalent of offline trade fair where you present your company and products, distribute catalogues, make contacts and develop your business.

What You Get with us?
Partners
What You Get with us?